Consultant and DSD partner David Selko  of Baltimore just checked in to report an odd issue he encountered while upgrading Sage ERP MAS 90 from version 4.30 to 4.50 today:
I am out to upgrade a client to 4.5. Get all the conversion work done, get the forms done, log a couple people in, then a user comes to me and says she can’t get in.

Immediate error

object PvxDax.PvxDictionary could not be initialized.

I uninstall the client, repair the client, run the regcom.bat file, register the pvxdax.dll file. No luck. Had this on two workstations. I call support and they say, your computers are messed up,

The work was all done, all the clients for 4.3 were removed and 4.5 installed. I start running around to put them back to 4.3 and support called back and says that it is possible that you don’t have Visual C++ 2008 installed.

The MAS90 workstation  setups installed fine without it and never mentioned anything about needing  it.

These machines were both missing dotnet. Anyway, installing the visual C++ fixed the issue. I ALMOST had to abandon the upgrade because of the missing files.

So if you see a workstation setup warn you about dotnet, this may be your issue.

 

And here is the file I needed to install:

http://www.microsoft.com/download/en/details.aspx?displaylang=en&id=29

Via: DSD of Baltimore Maryland – MAS90/MAS200/MAS500/SageCRM

© 2011, Wayne Schulz. All rights reserved. Sage 50, Sage 100, Sage 300 and Sage 500 are registered trademarks of Sage. Have additional unanswered questions about MAS90? You may contact Schulz Consulting here.

We publish an email newsletter each Tuesday at 3pm – join here.


Related posts you might want to review:

  1. Object ProvideX.Script is invalid
  2. Sage MAS 90 and 200 Object Interface course is Now Available Online – Anytime
  3. MAS90 Upgrade Tip Of The Day: Load Your Hot Fixes
  4. What’s New In The Latest MAS90 – MAS200 Upgrade or Product Update?
  5. Six Tips for a Smoother MAS90 or MAS200 Upgrade

Comments

Comments are closed.